Ti o ku Chlorine Oluyanju
-
DPD Colorimetry Chlorine Oluyanju CLG-6059DPD
DPD Colorimetry Chlorine Oluyanju CLG-6059DPDỌja yii jẹ olutupalẹ ori ayelujara chlorine aloku DPD ni ominira ni idagbasoke ati iṣelọpọ nipasẹ waile-iṣẹ. Irinṣẹ yii le ṣe ibasọrọ pẹlu PLC ati awọn ẹrọ miiran nipasẹ RS485 (Modbus RTUIlana), ati pe o ni awọn abuda ti ibaraẹnisọrọ iyara ati data deede.Ohun eloOluyanju yii le ṣe awari ifọkansi chlorine ti o ku ninu omi lori ayelujara laifọwọyi. Awọn gbẹkẹleorilẹ-bošewa DPD colorimetric ọna ti wa ni gba, ati awọn reagent ti wa ni laifọwọyi kun funwiwọn colorimetric, eyiti o dara fun ibojuwo ti ifọkansi chlorine aloku ninuilana ti chlorination ati disinfection ati ni nẹtiwọọki paipu omi mimu.Awọn ẹya:1) Gbigbe agbara jakejado, apẹrẹ iboju ifọwọkan.2) Ọna awọ awọ DPD, wiwọn jẹ deede diẹ sii ati iduroṣinṣin.3) Iwọn aifọwọyi ati isọdọtun aifọwọyi.4) Akoko itupalẹ jẹ awọn aaya 180.5) Akoko wiwọn le ṣee yan: 120s ~ 86400s.6) O le yan laarin aifọwọyi tabi ipo afọwọṣe.7) 4-20mA ati RS485 o wu.8) Iṣẹ ipamọ data, atilẹyin U disk okeere, le wo itan-akọọlẹ ati data isọdiwọn.Orukọ ọja Online Chlorine Oluyanju Ilana wiwọn DPD colorimetry Awoṣe CLG-6059DPD Iwọn Iwọn 0-5.00mg/L(ppm) Itọkasi Yan iye iwọn ± 5% ti o tobi ju tabi ± 0.03 mg/L (ppm) Ipinnu 0.01mg/L(ppm) Ibi ti ina elekitiriki ti nwa 100-240VAC, 50/60Hz Afọwọṣe Ijade 4-20mA o wu, Max.500Ω Awọn ibaraẹnisọrọ RS485 Modbus RTU Itaniji Ijade 2 tan-an/PA awọn olubasọrọ, eto ominira ti awọn aaye itaniji Hi/Lo, pẹlu eto hysteresis, 5A/250VAC tabi 5A/30VDC Ibi ipamọ data Iṣẹ ipamọ data, atilẹyin U disk okeere Ifihan 4.3inch awọ LCD iboju ifọwọkan àpapọ Awọn iwọn / iwuwo 500mm * 400mm * 200mm (Ipari * iwọn * iga) 6.5KG (Ko si reagents) Reagent 1000mLx2, nipa 1.1kg lapapọ; le ṣee lo nipa 5000 igba Iwọn Aarin Awọn ọdun 120 ~ 86400; aiyipada 600s Akoko wiwọn ẹyọkan Nipa awọn ọdun 180 Ede Chinese/Gẹẹsi Awọn ipo iṣẹ Iwọn otutu: 5-40 ℃
Ọriniinitutu: ≤95% RH (ti kii ṣe itọlẹ)
Idoti: 2
Giga: ≤2000m
Apọju: II
Oṣuwọn sisan: 1L / min ni a ṣe iṣeduroAwọn ipo iṣẹ Oṣuwọn sisan ayẹwo: 250-300mL / min, Ayẹwo titẹ titẹ sii: 1bar (≤1.2bar)
Apeere otutu: 5 ~ 40 ℃ -
Oluyanju Chlorine Residual Online/Chlorine Dioxide Analyzer
★ Awoṣe No: CL-2059B
★ Ijade: 4-20mA
★ Ilana: Modbus RTU RS485
★ Idiwon Parameters: Residual Chlorine/Chlorine Dioxide,Iwọn otutu
★ Ipese Agbara: AC220V
★ Awọn ẹya ara ẹrọ: Easy lati fi sori ẹrọ, ga konge ati kekere ni iwọn.
★ Ohun elo: Omi mimu ati awọn eweko omi ati bẹbẹ lọ
-
Oluyanju Chlorine Residual Online Lo Fun Omi Egbin Iṣoogun
★ awoṣe No: FLG-2058
★ Ijade: 4-20mA
★ Ilana: Modbus RTU RS485
★ Idiwon Parameters: Residual Chlorine/Chlorine Dioxide,Iwọn otutu
★ Ipese Agbara: AC220V
★ Awọn ẹya ara ẹrọ: Easy lati fi sori ẹrọ, ga konge ati kekere ni iwọn.
★ Ohun elo: Omi idọti iṣoogun, omi idọti ile-iṣẹ ati bẹbẹ lọ
-
Oluyanju Chlorine Residual Online Lo Fun Omi Mimu
★ Awoṣe No: CLG-6059T
★ Ilana: Modbus RTU RS485
★ Iwọn Iwọn: Chlorine Residual, pH andTemperature
★ Ipese Agbara: AC220V
★ Awọn ẹya ara ẹrọ: 10-inch awọ iboju ifọwọkan iboju, rọrun lati ṣiṣẹ;
★ Ni ipese pẹlu awọn amọna oni-nọmba, pulọọgi ati lilo, fifi sori ẹrọ ti o rọrun ati itọju;
★ Ohun elo: Omi mimu ati awọn eweko omi ati bẹbẹ lọ
-
Online Aloku Chlorine Oluyanju
★ Awoṣe No: CL-2059S&P
★ Ijade: 4-20mA
★ Ilana: Modbus RTU RS485
★ Ipese Agbara: AC220V tabi DC24V
★ Awọn ẹya ara ẹrọ: 1. Awọn ese eto le wiwọn péye chlorine ati otutu;
2. Pẹlu oluṣakoso atilẹba, o le mu awọn ifihan agbara RS485 ati 4-20mA jade;
3. Ni ipese pẹlu awọn amọna oni-nọmba, pulọọgi ati lilo, fifi sori ẹrọ ti o rọrun ati itọju;
★ Ohun elo: Omi egbin, omi odo, adagun odo
-
Online Aloku Chlorine Oluyanju
★ Awoṣe No: CL-2059A
★ Ijade: 4-20mA
★ Ilana: Modbus RTU RS485
★ Ipese Agbara: AC220V tabi DC24V
★ Awọn ẹya ara ẹrọ: Dekun esi, lagbara egboogi-kikọlu agbara
★ Ohun elo: Omi egbin, omi odo, adagun odo